Upgrade Instructions for Classic Units
From Dedicated Micros USA Wiki
- UPGRADE INSTRUCTIONS
Make sure the computer is connected to the Digital unit and/or that computer can communicate with the Digital unit via the network port. If unsure how to connect, please consult with your IS/IT department, or consult a network specialist for assistance.
Put the Digital Unit into 'Bootloader mode' by going to TIME, DATE AND LANGUAGE menu page
Select SYSTEM SHUTDOWN menu option
When prompted to hold in camera 1, hold down Camera 2 instead
The unit should automatically restart after a few seconds
After the unit restarts, "Halted in Bootloader" should appear at the bottom of the screen
Unzip the software to your local disk (default, C:\DM SOftware). Select the correct software from the DM Software directory
Double click on "FTP.EXE" to run upgrade program
Type IP Address of unit to be upgraded in space labeled "Select Unit"
Click the 'Download' button
They should see the following messages appear below: Connect: (ip address will be listed)
230 User logged in, proceed STOR \bin\zip.cof 150 File status okay; about to open data connection STOR disk.zip 150 File status okay; about to open data connection QUIT 221 Service closing control connection. Logged out if appropriate.
- if the customer gets any error messages about connection failed or connection timed out or any syntax errors you can have the customer restart the pc or try from a different pc.*
Wait for 2 blue status bars to finish at bottom of the FTP Download software screen
Power down the unit from the mains
Wait 10 seconds
Apply power to the unit. The unit will now upgrade the software automatically